TM 10-3930-641-20
(Sheet 7 of 10)
CAB HEATER AND DEFROSTER REMOVAL/INSTALLATION (CONT)
LOCATION/ITEM
ACTION
REMARKS
2. Two clamps (3)
Slide loosened clamps over ends of heater
hoses (4).
3. Two heater hoses (4)
a.
Connect hoses to fittings on heater unit.
b. Slide clamps over hose and fittings and
tighten clamps.
4. Two 1/2-13NC forged eyebolts with
Install on cover (6).
a.
nuts and washers (5)
b. Attach hoist to eyebolts as shown.
c.
Lift cover above Roll-Over Protective
Structure (ROPS).
d. Position cover on ROPS.
Lift one side of cover, b!ock it securely and
e.
remove eyebolt.
Remove second eyebolt the same way.
f.
Position on ROPS.
5. Cover (6)
2-446