TM 10-3930-641-34-2
TEE TEST PROCEDURE FOR HYDRAULIC SYSTEM (CONT)
(Sheet 19 of 27)
LOCATION/ITEM
ACTION
REMARKS
3.
Manual load valve
Close valve slowly until you get 1000 psi
(703 kgs/sq. meter).
NOTE
At each rpm change you will need to adjust the
manual control valve.
4.
Oil temperature
Record.
5.
Flow rate (gpm)
Record.
CAUTION
Immediately after the engine is stopped, remove
the Blocking Plate Assembly from the pressure
line for the pump to prevent any possible
damage later.
Go on to Sheet 20
7-142