TM 10-3930-675-10-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
Table 1. Preventive Maintenance Checks and
Services (PMCS) for RTCH-RT 240V2 - Continued.
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
9
Before
Hydraulic
a. Check for damage and leaks.
Class III leaks are evident.
Reservoir
and Sight
Gage
NOTE
Boom must be fully lowered and retracted and RTCH parked on
level ground before checking hydraulic oil level in reservoir.
Engine should be stopped at least five minutes.
b. If level is low, before adding oil, remove Hydraulic oil level is below
one of the fill plugs from the oil filter sight gage.
cover plates at the top of the hydraulic
oil tank and allow the RTCH to rest
another five minutes. Recheck the oil
level. If level is still low, add oil only
through one of the fill points. Refer to
add oil IAW instructions in WP 0012 00.
c. Check hydraulic oil in oil level sight
gage. If hydraulic oil is visible in sight
gage, level is okay. If level is low, add
oil IAW instructions in WP 0012 00.
FILL POINT
DO NOT
SIGHT
FILL
GAGE
THROUGH
THESE
PORTS
FILL
POINT
HYDRAULIC RESERVOIR
0013 00-3