TM 10-3930-675-10-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
Table 1. Preventive Maintenance Checks and
Services (PMCS) for RTCH-RT 240V2 - Continued.
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
NOTE
To ensure an accurate reading, RTCH must be parked on level
ground.
15
Before
Engine Oil
Check engine oil level on dipstick.
Level
Maintain oil level with indicator marks
between LOW and HIGH. If level is low,
add oil IAW instructions in WP 0012 00.
ENGINE OIL FILL
ENGINE
OIL DIPSTICK
350-040
16
Before
Battery Stor-
Open battery storage compartment and
Damage or missing parts that
visually check batteries, battery cables,
age Com-
would impair operation is
partment
evident.
equipped), and master battery switch for
damage.
NOTE
Perform the following checks if forklift kit is to be used.
17
Before
a. Ensure all retaining and locking pins Retaining or locking pins are
are present and properly secured.
missing.
b. Inspect hydraulic hoses and quick-dis- Hydraulic hoses or quick-
connects for dirt, damage, and proper disconnects are damaged.
operation.
0013 00-5