TM 10-3930-675-20-1
0010 00-7
OVERLOAD PROTECTION TROUBLESHOOTING - CONTINUED
0010 00
Table 5. Error Code 134 - Left Lift Cylinder Piston Pressure Sensor or Circuit Failure Troubleshooting Procedures -
Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 134 - Right Lift Cylinder Pressure
Sensor or Circuit Failure - Continued
6. If voltage is present in step 5,
check continuity between
connector X159 pin 3 and
junction box X167 pin 16,
between connector X159 pin
4 and junction box X167 pin
17, and between connector
X159 pin 5 and junction box
X167 pin 18.
a. If continuity is not present,
repair or replace connectors
(WP 0111 00).
b. If problem persists, notify
SRA.
Table 6. Error Code 135 - Left Lift Cylinder Piston Pressure Sensor or Circuit Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 135 - Left Lift Cylinder Piston
Pressure Sensor or Circuit Failure
1. Inspect left lift cylinder
sensors and connector for
damage and secure mounting.
Two sensors are located at
locking valve at base of lift
cylinder.
2. Remove cover from junction
box X167, located at forward
end of engine compartment.
Start
engine
and
check
voltage between pin 16 and
pin 17. Voltage should be 20-
25V.
DIAG SERVO
1(13)
SYSTEM POWER
24.00V
POWER RI CAN
24.00V
POWER LE CAN
24.00V
10V REF OUT
10.00V