TM 10-3930-675-20-2
0077 00-3
TOPHANDLER PROXIMITY SWITCH JUNCTION BOXES REPLACEMENT - CONTINUED
0077 00
INSTALLATION - CONTINUED
NOTE
Perform step 2 in five places.
2.
Install fitting (10) and plastic nut (11) to bottom of junction box (3).
3.
Install terminal blocks (7) and terminal block holder (6) to junction box (3) with two screws (5).
NOTE
Perform steps 4 and 5 in five places.
4.
Push cable (12) into junction box (3) and use jewelers screwdriver to connect wires (8) to terminal blocks (7).
5.
Install grommet (13) and cable nut (14) to junction box (3). Tighten cable nut.
6.
Install cover (2) to junction box (3) with four screws (1).
7.
Perform boom and tophandler calibration (WP 0197 00).
END OF WORK PACKAGE
1
2
3
4