TM 10-3930-675-20-2
0110 00-3
SLAVE STARTING RECEPTACLE REPLACEMENT - CONTINUED
0110 00
RIGHT SLAVE STARTING RECEPTACLE INSTALLATION - CONTINUED
5.
Connect battery cables (WP 0108 00).
LEFT SLAVE STARTING RECEPTACLE REMOVAL
1.
Remove two screws (19), lockwashers (20), and cables (21) from rear of slave starting receptacle (13). Discard lock-
washers.
2.
Remove cap (14) from slave starting receptacle (13).
3.
Remove four locknuts (15), eight washers (16), four screws (17), slave starting receptacle (13), and cord of cap (14)
from mounting plate (18). Discard locknuts.
1,2
3,4,5
6
13
14
15,16,17
19,20
21
21
18