TM 10-3930-675-20-2
0170 00-3
BOOM FOLDING CONTROL VALVE REPLACEMENT - CONTINUED
0170 00
INSTALLATION - CONTINUED
4.
Check oil level in hydraulic reservoir (LO 10-3930-675-12).
5.
Start engine (TM 10-3930-675-10), operate control valve levers, and check for leaks.
6.
Install new tiedown straps as necessary to support hydraulic hoses.
NOTE
Replace hydraulic reservoir return filters after 100 hours of operation (WP 0183 00).
END OF WORK PACKAGE