TM 10-3930-675-24-1
OVERLOAD PROTECTION TROUBLESHOOTING - CONTINUED
0011 00
Table 6. Error Code 135 - Left Lift Cylinder Piston Pressure Sensor or
Circuit Failure Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 135 - Left Lift Cylinder Piston 5. Disconnect sensor harness a. If no voltage (24V) is found,
Pressure Sensor or Circuit Failure - Continued
768-4 and check voltage (24V)
continue with step 6.
between 1 and 3 with the b. If voltage (24V) is found,
check sensor pins and harness
for damage, seal, and tight fit.
c. Replace damaged sensor and
harness (WP 0102 00).
6. Remove the engine cover to a. If no voltage (24V) is found at
X167 between pins 16 and 17,
gain access to X167. Check
voltage (24V) at X167 between
pins 16 and 17 and check voltage
(<2V) between pins 17 and 21 b. If no voltage (2V) is found at
X167 between pins 17 and 21,
00-9).
9).
c. Replace damaged sensor and
harness (WP 0102 00).
d. Repair or replace damaged
wires or connectors (WP 0113
00).
e. Replace damaged or open
harness (WP 0113 00).
0011 00-10