TM 10-3930-675-24-2
INSTRUMENT PANEL SWITCHES, GAGES, AND PANEL LAMPS REPLACEMENT - CONTINUED
0073 00
GAGE REMOVAL
Perform steps 1 and 2 of Rocker Switch Removal to gain access to rear of gage.
1.
To remove gage lamp, refer to Instrument Panel Lamp Removal.
2.
NOTE
Perform steps 3 and 4 for fuel gage.
3.
Disconnect instrument panel wiring harness connector (25) from rear of gage (19).
4.
Remove retainer (20) and gage (19) from switch/gage panel (1).
NOTE
Perform steps 5 and 6 for hour meter gage.
5.
Disconnect instrument panel wiring harness connector (24) from rear of gage (21).
6.
Remove two nuts (23), retainer (22), and gage (21) from switch/gage panel (1).
19
21
20
1
22
25
23
24
GAGE INSTALLATION
NOTE
Perform steps 1 and 2 for hour meter gage.
1.
Install gage (21) on switch/gage panel (1) with retainer (22) and two nuts (23).
2.
Connect instrument panel wiring harness connector (24) to gage (21).
NOTE
Perform steps 3 and 4 for fuel gage.
0073 00-6