TM 10-3930-675-24-2
BOOM-TO-BOOM EXTENSION FLEXIBLE CONVEYER MAINTENANCE - CONTINUED
0163 00
INSTALLATION - CONTINUED
9.
Using new tiedown straps, install boom wiring harness (3) and cable (6) along right side of boom (4).
10.
Connect cable (6) connector (7) to connector (8).
11.
Connect boom wiring harness (3) connector (5) to connector (1) and install two screws (2).
2
1
3
4
8
5
7
6
12.
Return boom to operational position (TM 10-3930-675-10) and check for leaks.
13.
NOTE
Replace hydraulic reservoir return filters after 100 hours of operation (WP 0185 00).
END OF WORK PACKAGE
0163 00-7/(0163 00-8 Blank)