TM 10-3930-675-24-2
TOPHANDLER HYDRAULIC SPREADER MOTOR REPLACEMENT - CONTINUED
0167 00
INSTALLATION
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance
during procedure. Ensure that any lifting device used is in good condition and of suitable load
capacity. Keep clear of heavy parts supported only by lifting device. Failure to follow this warning
may result in death or injury to personnel.
Spreader motor weighs approximately 150 lb (68 kg). Lifting device must have sufficient capacity
to lift motor.Failure to follow this warning may result in injury to personnel.
NOTE
Ensure spreader motor is oriented to allow connection of hydraulic manifold.
1.
Using suitable lifting device, nylon sling, and with assistance, install spreader motor (10) on mounting weldment (17).
NOTE
Ensure screws are installed from bottom up as noted in removal.
2.
Install ten screws (16), washers (18), and nuts (19) to secure spreader motor (10). Tighten screws in an even pattern in
accordance with Torque Limits (WP 0286 00).
NOTE
Ensure O-rings are lubricated with lubricating oil prior to installation.
3.
Position hydraulic manifold (11) with hoses and new O-rings (12) on spreader motor (10) and secure with four socket
head screws (13).
4.
Position chain (15) on drive sprocket (14).
10
11,12
13
18,19
17
350-811
16
14
15
0167 00-6