TM 10-3930-675-24-2
BOOM LIFT CYLINDER REPLACEMENT - CONTINUED
0252 00
INSTALLATION - CONTINUED
9.
Position new O-ring and valve (1) and secure to cylinder (3) with four screws (2).
10.
Close emergency lowering and float valves.
2
1
3
350-393
11.
12.
Start engine (TM 10-3930-675-10), operate lift cylinders, and check for leaks.
13.
NOTE
Replace hydraulic reservoir return filters after 100 hours of operation (WP 0185 00).
END OF WORK PACKAGE