TM 10-3930-675-24-2
MOUNTING ENGINE ON REBUILD STAND - CONTINUED
0270 00
INSTALLATION - CONTINUED
1.
Remove water header plate (1) from exhaust side of cylinder block (3) as follows:
a.
Disconnect wiring harness from coolant temperature sensor.
b.
Remove four screws (2), thermostat housing support (5), and gasket (4). Discard gasket.
2
3
1
4
COOLANT
TEMPERATURE
SENSOR
5
c.
Remove four screws (8), water heater housing (6), and gasket (7) from water header plate (1). Discard gasket.
7
1
6
8