TM 5-3810-306-34
OIL COOLER BYPASS VALVE INSTALLATION
TOOLS:
SUPPLIES:
EQUIPMENT CONDITIONS:
Hydraulic system shutdown and pressure relieved from lines. (Refer to TM 5-3810-306-
20.)
Negative battery cable disconnected at shunt. (Refer to TM 5-3810-306-20.)
REMOVAL:
1.
CYLINDER (2).
a. Tag and disconnect two electrical connectors (3)
to solenoid valve (1).
b. Tag and disconnect air line to solenoid valve (1).
flatwashers (6) and remove air cylinder (2),
d. Remove nut (10) and bracket (11) from air
cylinder (2).
e. Remove fittings and separate valve (1) from air
cylinder (2). Retain fittings for installation.
2.
REMOVE BYPASS VALVE (7).
a. Tag and disconnect three hydraulic lines from
bypass valve (7).
Remove fittings and
preformed packing. Discard preformed packing.
Remove bypass valve (7).
13-70