h. Tighten nuts on terminals with fastener tool.
NOTE
It may be necessary to move the horizontal
i. Place retention clip (11) over each terminal and
exhaust pipe to align the U-bolt and spacer
return fastener tool (10) to storage position.
with welded brackets.
b. Install horizontal exhaust shield (7) on generator
j. Close terminal door (8). Secure weather boot
set (8) and secure with five screws (6).
(9) around cable (7).
c. Install spacer (5) and U-bolt (4) on horizontal
See Figure 4-17 (Sheet 3 of 4) for installation of fuel
exhaust shield (7) with two flat washers (3), two lock
hose.
washers (2) and two nuts (1). Do not tighten at this time
because of alignment with vertical exhaust shield (4) and
k. Open storage door (12) and remove fuel hose
(13) from storage box.
See Figure 4-17 (Sheet 1 of 4) for installation of generator
l. Remove dust cap (14) and connect fuel hose
set.
(13) to elbow (15) on fuel tank (16).
d. Using a forklift truck, position generator set (1)
m. Remove dust cap (17) and connect fuel hose
on frame slide rails (2).
(13) to external fuel fitting (18).
e. Align mount holes in generator set (1) with
See Figure 4-17 (Sheet 4 of 4) for installation of generator
mounting holes in generator set slide (2).
set.
f. Install eight flat washers (3), four lock washers
CAUTION
(4), four nuts (5) and four bolts (6) to secure generator set
When generator set is returned to the stowed
(1) to slide rails (2).
position, fuel hose and power cable must be
kept clear of the slides. Fuel hose and power
See Figure 4-17 (Sheet 2 of 4) for connection power cable
cable could be damaged if pinched in slide.
to generator set.
n. Using two personnel, release retention latches
g. Connect power cable (7) to generator set (1) as
(19) simultaneously and carefully push generator set (1,
follows:
Figure 4-17 Sheet 1 of 4)
back into
stowed position
until
retention latches locks.
(1)
Open terminal door (8).
.
CAUTION
(2) Insert power cable (7) through weather
The vertical and exhaust pipes should be
boot (9) into terminal compartment.
aligned concentrically (center of the vertical
exhaust pipe centered on the horizontal pipe)
(3) Remove fastener tool (10). Raise retention
to prevent water from running down into the
clips (11) on terminals.
generator exhaust.
(4)
Connect black wire to L1.
o. If exhaust pipe (19) does not clear the vertical
(5)
Connect white wire to terminal L2.
pipe (19) down until it is clear.
(6)
Connect red wire to terminal L3.
(7)
Connect green wire to terminal L0.
q. Install generator locking bolts (21).
(8) If required, insert ground wire through slot
r. If required, connect ground wire to generator
on load terminal board marked GND.
Change 5
4-29