TM 55-8115-202-14
Section XX. MAINTENANCE OF GENERATOR SLIDE ASSEMBLY
f. Drill out two rivets (12) and remove two
4-70.
General.
generator locking bolt lanyards (13) from generator
The generator set slide assembly is located in front of the
mount plate (5).
refrigeration container and provides ease of servicing,
maintenance, removal and installation of the generator
4-73.
Installation.
set.
See Figure 4-18 for installation of the generator slide
4-71.
Inspection.
assembly.
Inspect generator set slide assembly for obvious damage
and defects.
a. Install three slide mounts (11) on bottom of each
slide (9) and secure with six screws (10).
4-72.
Removal.
b. Install two slides (9) on frame (14) and secure
See Figure 4-18 for removal, inspection and installation
with six flat washers (8), six lock washers (7) and six
of the generator slide assembly.
screws (6). Hand tight only at this time.
c. Position generator mount plate (5) on both slides
(9) and secure with twelve flat washers (3), twelve lock
b. Remove twelve screws (1), twelve lock washers
washers (2) and twelve screws (1).
(2), twelve flat washers (3). Discard lock washers.
d. Tighten six screws (6) installed in step b.
c. Remove eight screws (4) and generator mount
plate (5).
e. Secure two generator locking bolt lanyards (13)
to generator mounting plate (5) with two rivets (12).
d. Remove six screws (6), six lock washers (7),
and six flat washers (8) from each of the two slides (9).
f. Move generator slide assembly back and forth to
Discard lock washers.
ensure each of movement.
e. Remove six screws (10) and three slide mounts
(11) from each slide (9).
Change 5