TM 55-8145-201-14
1-13. COMPONENT TECHNICAL PRINCIPLES OF OPERATION - cont.
f.
Power Cable. The power cable distributes electrical power from the generator set to the refrigeration unit.
The receptacle end of the cable connects to the refrigeration unit power cable. The electrical leads on the
opposite end connect to the generator set terminal box (refer to TM 5-6115-585-12/34).
g.
Exhaust Extension. The exhaust extension diverts exhaust gases from the generator set to the top of the
container frame. A dust cap on top of the exhaust tube prevents rain, birds, and contaminants from entering
the exhaust tube.
h.
Refrigeration Unit. For detailed Refrigeration Unit component principles of operation, refer to TM 9-4110-
252-14.
i.
Generator Set. For detailed Generator Set component principles of operation, refer to TM 5-6115-585-1134.
1-10