TM 55-8145-201-14
Table 2-1. Operator Preventive Maintenance Checks and Services for Model SC-219 - cont.
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
11
Before
Temperature
a. Inspect cover for damaged or
Recorder
missing latch.
b. Inspect for cracked or missing
cover glass.
c. Inspect for loose sensing bulb
connection at bottom of recorder.
12
Before
Right Side Panel
a. Inspect for obvious damage,
Side panel split, cracked or
cracks, splits or delamination.
punctured through interior.
b. Check for loose or missing
fasteners.
c. Inspect container upper and lower
Container frame cracked.
side frame for cracks, splits, and
broken welds.
INTERIOR
13
Before
Rear Doors
Open rear doors and inspect right and
Door seal badly torn.
left door seals for cuts, tears and loose
seal material.
14
Before
Light
With power applied, rotate light
switch to on position. Check that bulb
lights up.
15
Before
Floor
a. Inspect container floor for
Floor punctured through to
punctures and obvious damage.
exterior.
b. Inspect floor for blocked or
clogged
drain screens (one at each corner).
Clean screens as required.
EXTERIOR
16
During
Refrigeration
Perform During PMCS on
Refrigeration unit not
Unit
refrigeration unit per
operational.
TM9-4110-252-14.
17
During
Generator Set
If required for operation, perform
operational.
TM5-6115-585-12/34.
2-11