TM 55-8145-201-14
2-10. ASSEMBLY AND PREPARATION FOR USE - cont.
b.
Temperature Recorder. Before using the refrigerated container, prepare temperature recorder as follows:
(1) Unfasten latch (6) and open cover (1).
(2) Depress stylus lifter (9). Make sure stylus (7) clears paper chart (5).
(3) Remove knurled knob (2) from of chart platen (3).
(4) If installed, remove old paper chart (5).
CAUTION
To prevent damage to temperature recorder, do not over wind timer movement.
(5) Insert winding key (11) into winder hole (10) and wind timer movement clockwise. Be careful not to over
wind.
NOTE
Spare charts are stored in the document holder.
(6)
Position new chart (5) on chart platen (3). Make sure chart fits under four guide tabs (4) on face plate
(8).
(7)
Rotate chart (5) so that correct day (1 to 31) and morning (M) or night (N) is alined with STARTING
TIME arrow on face plate (8).
(8)
Install knurled knob (2) on chart platen (3).
(9)
Slowly release stylus lifter (9) so that stylus rests on chart (4).
(10) Close cover (i) and fasten latch (6).
2-14