TM 55-8145-201-14
4-26. ELECTRIC POWER CABLE REIPAIR - cont.
e. Repair.
NOTE,
If any connector component is defective, replace entire connector.
Replace defective components.
f.
Assembly.
(1) Position nut (9), washer (10), bushing (5), and sleeve (4) on cable (8).
(2) Loosen four screws (3) and connect wiring (7) to terminal block (2) as shown.
(3) Aline terminal block (2) with housing (1) and push block into housing.
(4) Slide sleeve (4), bushing (5), and washer (10) into housing (1).
(5) Screw nut (9) onto housing (1) and tighten setscrew (6).
g. Installation.
(1) Connect power cable to generator set (TM 5-6115-585-12/34).
(2) Connect power cable to refrigeration unit (TM 9-4110-252-14).
4-41