TM 55-8145-201-14
4-28. LIGHT ASSEMBLY (INTERIOR) REPAIR - cont.
(4) Inspect wiring (15) for cut, burned, or deteriorated insulation.
(5) Inspect conduit (5 and 7) for corrosion.
e. Repair. Replace defective components.
f.
Assembly.
(1) Position nipple (2) in container wall (29).
(2) Apply cement to ends of adapters (1) and 3). Before cement dries, install adapters
on nipple (2).
(2) Install connector (4) on adapter (3).
(3) Connect conduit (5) to conduit (7) with connector (6)
(4) Install locknut (9) and connector (8) on lamp holder (10).
(5) Install lamp holder (11) on conduit (7) and tighten connector (8).
(6) Install locknuts (12 and 14) on nipple (13).
(6) Install nipple (13) on lamp holder (11),then tighten locknut (12).
(7) Install box (16) on nipple (13) and tighten locknut (14).
(8) Position assembled components on container wall and push conduit (5) into
adapter (4).
(9) Secure conduit (5 and 7) to container wall (29) with seven clamps (28) and
screws (27).
(10) Secure box (16) on container wall (29) with two screws (17).
(11) Install wiring (15) from lamp holder (11) out through nipple (2) in container
wall (29).
(12) Install wiring (15) from box (16) to lamp holder (11).
(13) Connect wiring (15) to fixture (21) as tagged during removal.
(14) Connect wiring (15) to switch (19) as tagged during removal.
(15) Install gasket (18), switch (19) and two outer screws (20) on box (16).
(16) Install fixture (21) on lamp holder (11) with two screws (22).
4-48