TM 9-3950-253-13&P
0075
HOOK ARM SENSOR INSTALLATION AND CALIBRATION - Continued
NOTE
Ensure stowage control toggle switch is set to OFF position.
5.
Adjust nut (Figure 16, Item 4) until face of sensor is 0.0625 to 0.1875 in. (2 to 3 mm) from sensor plate
(Figure 16, Item 6).
6.
Slide hook arm sensor (Figure 16, Item 2) on bracket (Figure 16, Item 3) toward sensor plate (Figure 16,
Item 6) and identify position where sensor light (Figure 16, Item 1) turns on. Tighten nut (Figure 16, Item 5)
at that position.
7.
Return hook arm to stowed position (PLS: TM 9-2320-364-14&P, HEMTT: TM 9-2320-326-14&P).
END OF TASK
END OF WORK PACKAGE