TM 10-3930-641-20
(Sheet 2 of 4)
WATER PUMP REMOVAL/INSTALLATION (CONT)
REMARKS
ACTION
LOCATION/ITEM
This will permit belt tightener to move away from water
REMOVAL
pump.
1. Vee belt set
Tag and disconnect from housing assembly.
2. Heater hose (2 each) (1)
Disconnect from valve assembly.
3. Clips holding hoses to water cooler
Disconnect hose going from housing assembly
4. Housing assembly
to inlet elbow on radiator.
Remove.
5. Housing assembly capscrews (2)
NOTE
Be sure all capscrews are removed.
Remove.
6. Housing assembly (3)
7. Four capscrews (4) at outlet side
Remove.
2-226