TM 10-3930-641-34-2
HAND MEETING UNIT REMOVAL/INSTALLATION (CONT)
(Sheet 2 of 4)
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
1.
Plates (1) and (2)
Remove.
2.
Detent block (3)
a. Remove by removing four detent block
capscrews and washers.
b.
Remove shims.
3.
Nuts (5)
a. Remove outer nuts.
b.
Loosen inner nuts to end of threads.
c.
Slide pins (4) out.
4.
Four hydraulic lines (6)
Disconnect and identify.
TA098958
Go on to Sheet 3
6-15