TM 10-3930-641-34-2
TEE TEST PROCEDURE FOR HYDRAULIC SYSTEM (CONT)
(Sheet 18 of 27)
LOCATION/ITEM
ACTION
REMARKS
4.
Flow rate (gpm)
Record.
NOTE
Make a comparison of the test data with the
data on Chart B. The information on Chart B
is the maximum for best performance.
NOTE
Tests 15 thru 22 are the same except for the
Test 15 - 600 rpm
engine rpms. Follow the procedure, changing
Test 16 - 800 rpm
the engine rpms for each test, according to the
Test 17 - 1000 rpm
list under REMARKS and Chart B. Record the
Test 18 - 1200 rpm
data for each test.
Test 19 - 1400 rpm
Test 20 - 1600 rpm
Test 21 - 1800 rpm
Test 22 - 2000 rpm
TESTS 15 THRU 22
PUMP TEST FOR AERATION
1.
Manual load valve
Open fully.
2.
Engine
Start and run at 600 rpm.
Go on to Sheet 19
7-141