TM 10-3930-675-10-2
OPERATION UNDER UNUSUAL CONDITIONS - CONTINUED
0006 00
SLAVE STARTING
0006 00
WARNING
When slave starting RTCH, use NATO slave cable that DOES NOT have loose or missing insula-
tion.
DO NOT proceed if suitable cable is not available.
DO NOT use civilian-type jumper cables.
The RTCH-RT 240V2 is equipped with a 24V, negative ground electrical system. The RTCH has two NATO slave
receptacles. One receptacle is located on the left side of the RTCH within the battery box. The other receptacle is located on
the right side of the RTCH to the rear of the right front tire.
NOTE
Ensure both RTCH and booster vehicle are equipped with serviceable NATO slave receptacles.
1.
Connect slave cable to booster vehicle slave receptacle.
LEFT
RIGHT
SLAVE
SLAVE
RECEPTACLE
RECEPTACLE
LEFT SIDE OF RTCH
RIGHT SIDE OF RTCH
374M-0027
0006 00-2