TM 10-3930-675-20-10016 00-5INPUT AND OUTPUT SIGNALS FOR STEERING ECU (792) TROUBLESHOOTING - CONTINUED0016 00Table 8. Error Code 412 - Short Circuit Failure of Ether Start Valve Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 412 - Short Circuit Failure of EtherStart Valve1. Check voltage at connectorX67 pin 3. Voltage should be22-26V.If voltage is not as specified,notify SRA to replace wire 673.2. Check voltage at connectorX16 pin 2. Voltage should be22-26V.If voltage is not as specified,notify SRA to replace wire A162and/or wire 162.3. Check voltage at connectorX29 pin 4. Voltage should be22-26V.If voltage is not as specified,notify SRA to replace wireA162A.4. Check voltage at connectorX150 pin 8. Voltage shouldbe 22-26V.If voltage is not as specified,notify SRA to replace wire 294.5. Check voltage at connectorX160 pin 11. Voltage shouldbe 22-26V.If voltage is not as specified,notify SRA to replace wireA1508.6. Check voltage at connectorX177 pin 11. Voltage shouldbe 22-26V.If voltage is not as specified,notify SRA to replace wire16011.7. Check voltage at steeringECU (792) connector pin 60.Voltage should be 22-26V.a. If voltage is not as specified,notify SRA to replace wireA1771.b. If voltage is not present,replace steering ECU (792)(WP 0079 00).Table 9. Error Code 413 - Short Circuit Failure of Boom Folding Supply Valve Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 413 - Short Circuit Failure of BoomFolding Supply Valve1. Check voltage at steeringconnector X198 pin 9.Voltage should be 22-26V.If voltage is not as specified,notify SRA to replace wire andconnector at valve 6043.2. Check voltage at steeringconnector X195 pin 8.Voltage should be 22-26V.If voltage is not as specified,notify SRA to replace wirebetween connector X195 andconnector X198.3. Check voltage at steeringECU (792) connector pin 59.Voltage should be 22-26V.a. If voltage is not as specified,notify SRA to replace wireA1958.b. If voltage is not present,replace steering ECU (792)(WP 0079 00).
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business