TM 10-3930-675-24-1
TROUBLESHOOTING INTRODUCTION - CONTINUED
0004 00
DIAG EXTRA FUNCTION - CONTINUED
EXTRA FUNCTION
8(13)
Ether start function input to ECU 792.
Signal from cab operational position proximity switch
ETHER START OK
0
to ECU 793.
CABIN OP. POS
0
Signal from cab in transport position proximity switch
CABIN SIDE POS.
to ECU 792.
0 = No voltage, 1 = Voltage 24V
EXTRA FUNCTION
9(13)
ECU communication in the CAN-BUS system.
1 = OK, 0 = Fault
Rx 792, STEERING
0
0
Rx 794, ENGINE
0
EXTRA FUNCTION
10(13)
Function not used on 3998, 3998R, or 7364.
ACT. SPEED CONTROL
0
MAX rpm
EXTRA FUNCTION
10(13)
Voltage to Autolube printed circuit board.
Used to activate a manual lube cycle.
SET OUTPUT SIG
1 = voltage (24V), 0 = No voltage
COENTRAL LUB
0
3998R/7364 only.
(+/-)
Autolube currently not used on 3998R.
0004 00-23