Table 1. Engine Troubleshooting Procedures (Non-Error Code) - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Engine Will Not Crank - Continued.
5. Check voltage (24V) at starter a. If no voltage (24V) is found,
check circuit breaker numbers
of S terminal while turning the
F50-1 and F50-2 for loose or
ignition switch to crank (WP
damaged connections.
b. If voltage is present (24V),
check starter and starter
solenoid for shorts or damage.
Replace shorted or damaged
00).
434-40171
6. Check starter relay 360 for Replace shorted, open, or
shorts, opens, or damage (WP damaged relay (WP 0074 00).
0113 00).
7. Check voltage (24V) at XK2 a. If voltage (24V) is not found,
pin 7 while turning the ignition
check voltage at X8 pin 3 (WP
31).
b. If voltage (24V) is present at
X8 pin 3, unplug X8 and check
X8 between pin 2 and 3 with
the ignition switch turned to
0007 00-2