TM 10-3930-675-24-1
AXLE BRAKE COOLING SYSTEM TROUBLESHOOTING - CONTINUED
0032 00
Table 2. Error Code 192 - Temperature in Rear Axle Above
Critical Threshold Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 192 - Temperature in Rear Axle 1. Enter
diagnostic
menu a. The normal temperature
Above Critical Threshold.
"EXTRA FUNCT" 12(13)
should be under 95F (35C).
Check temperature of WHEEL b. If the temperature reads
END REAR.
between 95 to 120F (35 to
49C), check the wheel hubs
for temperature above 203F
(95C).
c. A reading of 155 indicates a
possible short across the
temperature sensor or circuit.
2. Enter
diagnostic
menu a. Under normal or higher
"EXTRA FUNCT" 12(13) to
ambient temperatures, the
determine the brake cooling
BRAKE COOLING should be
status.
"1".
b. If the value is "0", perform
troubleshooting procedure for
of this work package.
3. Enter
diagnostic
menu a. The normal value should be
"EXTRA FUNCT" 4(13) to
"1".
determine the status of the b. If the value is "0", perform
fording switch. (Fording
troubleshooting procedure for
switch will cut off the cooling
fan.)
00).
4. Locate the temperature sensor a. The sensor should have a
762-2 inside the left rear hub.
Disconnect the sensor and
shorted or open.
check the resistance of the b. The sensor should not have
sensor. Check resistance to
continuity to ground.
ground.
c. Replace sensor if grounded,
shorted or open (WP 0093 00).
5. Disconnect the ECU (790) a. If continuity to ground, isolate
connector 1 and the 762-2
and check the following wires.
sensor. Check for continuity to b. Check the continuity to ground
ground at ECU (790)
connector 1 at pin 29 (WP
7).
c. Check for continuity to ground
0032 00-4