TM 10-3930-675-24-1
TOPHANDLER TWISTLOCKS AND FORKLIFT SENSOR TROUBLESHOOTING - CONTINUED
0047 00
Table 7. Error Code 246 - Tophandler Twistlock Unlocking Circuit Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 246 - Tophandler
Twistlock 1. Check wires and connectors at a. Repair or replace connectors
Unlocking Circuit Failure.
tophandler control valve and
(WP 0113 00).
tophandler junction box for b. Replace damaged wiring
damage.
harness (WP 0221 00).
2. Enter DIAG ATTACHMENT If no INPUT mA values display,
6(16) in the diagnostic menu. continue with troubleshooting
Activate the twistlock function procedure.
(override twistlocks).
DIAG ATTACHMENT 6(16)
3. Disconnect connector 6039 a. If no voltage (15 to 18V) is
TW-LOCK OUTPUT INPUT
from the tophandler twistlock
UNLOCKED 0.00V
0Ma
LOCKED
0.00V
0mA
unlocking solenoid. Turn the
ignition ON and check voltage
(15 to 18V) between both pins b. If voltage (15 to 18V) is found,
of the connector.
18 to 26 Ohms.
c. Replace open or faulty
d. Replace X189 to solenoids
wiring harness (WP 0221 00).
4. Disconnect connector X189 a. If no voltage (15 to 18V) is
from the tophandler junction
box. Turn the ignition ON.
wires
A3018A
through
Check voltage (15 to 18V) at
the mounted part of the
connector between pins J and
28).
K.
b. Repair or replace damaged
wires or connectors (WP 0113
00).
5. Disconnect
ECU
(791) a. Repair or replace damaged
connector 2. Inspect ECU and
connector (WP 0113 00).
connector pins for damage.
b. Replace ECU (791) (WP 0077
00).
NOTE
Multiple error codes associated with a common connec-
tor on ECU (791) may be the result of a short to ground
in the harness for the common solenoid voltage. (See
WP 0005 00
for troubleshooting multiple error codes.)
0047 00-8