TM 10-3930-675-24-2
ETHER COLD START SYSTEM MAINTENANCE - CONTINUED
0061 00
COLD START ACTIVATION SOLENOID REMOVAL - CONTINUED
3.
Disconnect ether supply tube (9) from elbow on underside of solenoid (4).
4.
Remove two screws (7), washers (8), and solenoid (4) from mounting bracket (10).
5.
Remove elbow from bottom of solenoid (4).
10
9
4
7,8
434-4005
0061 00-5