TYPE A SOLENOID REMOVAL
NOTE
Perform this procedure for each of 12 solenoids to be removed.
1.
Press in on retaining clip (6) on side of connector (1) and disconnect tophandler wiring harness connector from solenoid
(4).
NOTE
There are twelve solenoid valves on the tophandler control valve assembly; each has an orifice
underneath it. Ten have large orifices and two have small orifices. To aid in installation, note the
position of the smaller orifices during removal.
Carefully remove orifice from end of solenoid and retain for use on new solenoid during installa-
tion.
If the orifice remains in the valve port during removal, leave it there and install the solenoid valve.
2.
Remove two screws (2) and solenoid (4) from control valve (3).
3.
Remove O-ring (5) from solenoid (4). Discard O-ring.