TM 5-3810-306-34
TABLE 3-1. DIRECT AND GENERAL SUPPORT TROUBLESHOOTING (CONTD)
Malfunction
Test or Inspection
Corrective Action
65.
HOIST MOTOR FAILS TO START TURNING
Step 1. Excessive motor leakage.
a.
Install flow meter in motor outlet and check flow. If 50 gpm check shuttle valve in front port plate. Pressure
not loading plate causing plate to move away from cam ring.
b.
Step 2. Worn port plates.
a.
Step 3. Worn cam ring assembly.
a.
Step 4. Defective preformed packing on OD of front port plate.
a.
Step 5. Defective hoist motor.
a.
66.
HOIST MOTOR SHAFT PLAY
a.
Disassemble hoist motor and replace bearings. (Refer to page 15-54.)
Step 2. Hammering coupling on shaft.
a.
Coupling bore should be slip fit on shaft.
3-43