TM 5-3810-306-34
TABLE 3-1. DIRECT AND GENERAL SUPPORT TROUBLESHOOTING (CONTD)
Malfunction
Test or Inspection
Corrective Action
91.
ERROR CODE E08 DISPLAYED ON CONSOLE
Step 1. No acknowledgment signal from Anti-Two-Block switch relay (K2).
a.
92.
ERROR CODE E11 DISPLAYED ON CONSOLE
Step 1. Fallen below lower limiting value for measuring channel (length ).
a.
Check for defective cable from CPU to length sensor. (Refer to Malfunction No. 85.) Replace cable if
necessary.
b.
Replace defective length/angle cable reel. (Refer to page 14-10.)
c.
93.
ERROR CODE E12 DISPLAYED ON CONSOLE
Step 1. Fallen below lower limiting value for measuring channel (pressure-piston side).
a.
Check cable and plug from CPU to pressure transducer. (Refer to Malfunction No. 86.) Replace as
necessary.
b.
Replace defective pressure transducer (piston side). (Refer to page 14-20.)
c.
3-59