TM 5-3810-306-34
SECTION I. LOAD MOMENT INDICATOR SYSTEM MAINTENANCE
DISPLAY CONSOLE INSTALLATION
SUPPLIES: None
EQUIPMENT CONDITIONS:
Negative battery cable disconnected at shunt.
(Refer to TM 5-3810-306-20.)
REMOVAL:
1. REMOVE DISPLAY CONSOLE (1).
c. Remove connector nut (5) and rubber insert (9)
from metal insert (10) and insert cable (6)
a. Unscrew self-retaining screws (2) holding
through connector nut (5) and rubber insert (6).
console face (3) and separate console face (3)
Push both back over outer insulation of cable.
from console (1).
d. Insert wires and inner insulation of cable (6)
b. Tag and disconnect electrical wires of cable (6)
through metal insert (10) and into console (1).
from console terminal strip (4) on back of
console face (3). Resecure console face (3) to
NOTE
console (1) with screws (2).
Ensure that proper contact is made
c. Loosen connector nut (5) and pull cable (6)
between outer shield of cable (6) and
through connector nut (5) and out of console (1).
metal insert (10).
d. Remove adjusting knobs (7) and
remove
e. Slide rubber insert (6) and connector nut (5) to
console (1) from mounting bracket (8).
metal insert (10) and tighten connector nut (5).
INSTALLATION:
f. Reconnect wires of cable (6) to console terminal
strip (4) as tagged.
1. INSTALL DISPLAY CONSOLE (1).
g. Secure console face (3) to console (1) by
a. Position console (1) in mounting bracket (8) and
tightening self-retaining screws (2).
secure by installing adjusting knobs (7) through
bracket (8) and into sides of console (1).
2. CONNECT NEGATIVE BATTERY CABLE
AT
SHUNT. (REFER TO TM 5-3810-306-20.)
b. Unscrew self-retaining screws (2) holding
console face (3) and separate console face (3)
from console (1).
END OF TASK
14-2