TM 10-3930-675-20-2
0072 00-6
INSTRUMENT PANEL SWITCHES, GAGES, AND PANEL LAMPS
REPLACEMENT - CONTINUED
0072 00
GAGE REMOVAL
1.
Perform steps 1 and 2 of Rocker Switch Removal to gain access to rear of gage.
2.
To remove gage lamp, refer to Instrument Panel Lamp Removal.
NOTE
Perform steps 3 and 4 for fuel gage.
3.
Disconnect instrument panel wiring harness connector (25) from rear of gage (19).
4.
Remove retainer (20) and gage (19) from switch/gage panel (1).
NOTE
Perform steps 5 and 6 for hour meter gage.
5.
Disconnect instrument panel wiring harness connector (24) from rear of gage (21).
6.
Remove two nuts (23), retainer (22), and gage (21) from switch/gage panel (1).
GAGE INSTALLATION
NOTE
Perform steps 1 and 2 for hour meter gage.
1.
Install gage (21) to switch/gage panel (1) with retainer (22) and two nuts (23).
2.
Connect instrument panel wiring harness connector (24) to gage (21).
NOTE
Perform steps 3 and 4 for fuel gage.
25
19
20
1
21
22
23
24