TM 9-3950-253-13&P
0062
HEMTT STOWAGE ASSEMBLY INSTALLATION - Continued
WARNING
Use extreme caution when connecting hydraulic hoses. Contact with hydraulic oil
can damage eyes and skin. Wear eye protection, gloves, and protective clothing
while connecting hydraulic hoses.
Hydraulic fluid under pressure can penetrate the skin and cause injury, blindness,
or death. Pressure may build up in a hydraulic system. DO NOT perform any
hydraulic system service without first shutting down the engine to relieve system
pressure.
Any fluid spilled can cause a slip hazard and must be cleaned up immediately.
Failure to follow these warnings may result in death or serious injury to personnel.
Seek medical attention in the event of an injury.
11.
Route four lower hydraulic lines (Figure 21, Item 4) from under stowage assembly (Figure 21, Item 3) and
connect to fittings on control box (Figure 21, Item 2).
12.
Route two hydraulic hoses (Figure 21, Item 5) from under stowage assembly (Figure 21, Item 3) and
connect to quick connect fittings (Figure 21, Item 1).
Figure 21. Hydraulic Lines - HEMTT A4.
END OF TASK
03/15/2011Rel(1.10)root(maintwp)wpno(M582061)