TM 10-3930-641-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0012 00
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
ITEM
MAN-
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL
HOURS
b. If level is low, access hydraulic tank
53
After
0.1 Hours Hydraulic
by unlocking and raising floor plate
Cont.
Tank
and removing filler cap from tank.
Ensure filler cap gasket is present
and in good condition.
FLOOR PLATE
FILLER CAP
HYDRAULIC TANK
422-0045
c. Ensure strainer is present, in good
condition, and free of debris.
Remove debris from strainer, as
required.
d. Add oil (Item 7, 8, or 11, WP 0016
00) until level is at FULL
COLD
mark on sight gage or completely
fills sight gage.
e. Reinstall filler cap securely. Lower
floor plate and lock.
a. Check hoses, cables, and connec- a. Class III leaks or damage
54
After
Below Oper-
tions below right-side of operator
that would impair operation
ator Com-
compartment for damage or leaks.
are evident.
partment
b. Check cables for fraying or damage. b. Damage that would impair
operation is evident.
c. Check fuse box for missing fuses, c. Missing or damaged com-
damage, or corrosion.
ponents are evident, if
required for mission.
0012 00-20