TM 10-3930-641-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0012 00
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
ITEM
MAN-
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL
HOURS
d. Inspect filler cap gasket. Ensure it is d. Filler cap gasket is missing
48
After
Radiator
present and in good condition.
or damaged.
Cont.
e. Reinstall filler cap securely.
RADIATOR
FILLER CAP
422-0059
f. Check radiator grille for damage or
debris. Remove debris. If debris
cannot be removed or if grille is
damaged, notify Organizational
Maintenance.
g. Visually check radiator for signs of g. Class III leaks or damage
leakage or damage.
that would impair operation
are evident.
Check backup alarm and pintle hook Damage that would impair
49
After
Rear of
for damage.
operation is evident.
Machine
0012 00-17