TM 10-3930-641-20
(Sheet 3 of 8)
ELECTRICAL TEST EQUIPMENT (CONT)
OHMS SCALE (CONT)
USING THE OHMS SCALE (CONT)
TS-352 B/U
F Zero meter by turning the OHMS ZERO
A Set RANGE switch (1) to RX1.
ADJ (6) knob until needle (7) is over 0
on top scale.
B Put black (-) lead (2) into the OHMS
-DC AC jack.
G If needle will not zero, replace the bat-
teries. If needle still will not zero after
C Put red (+) lead (3) in the upper left
replacing the batteries, turn in the
OHMS jack.
D Turn FUNCTION switch (4) to OHMS.
E Touch the two probes (5) together.
SIMPSON 160
F Zero meter by turning the OHMS
A Set selector switch (1) on RX1.
ZERO ADJ (6) knob until needle (7)
B Put black (-) lead (2) in COM-jack.
is over 0 on top scale.
G If needle will not zero, replace the bat-
C Put red (+) lead (3) in + jack.
teries. If needle still will not zero after
replacing the batteries, turn in the
D Set polarity reversing switch (4) on
+DC.
E Touch the two probes (5) together.
Go on to Sheet 4
2-52