TM 10-3930-641-20
(Sheet 2 of 2)
AIR CLEANER HOUSING AND ELBOW REMOVAL/INSTALLATION (CONT)
REMARKS
ACTION
LOCATION/ITEM
REMOVAL
Disconnect from air cleaner sensing unit (1).
1. Wire assembly
Loosen.
2. Clamps (2)
Remove.
3. Capscrews (3)
NOTE
Weight of air cleaner housing and elbow is
50 lb (23 kg).
If disassembly is required, see Air Cleaner
Remove as a unit.
4. Air cleaner housing and elbow
INSTALLATION
1. Air cleaner housing and elbow
Install.
2. Capscrews (3)
Tighten.
3. Clamps (2)
Connect to air cleaner sensing unit (1).
4. Wire assembly
End
2-207