TM 10-3930-641-20
(Sheet 5 of 8)
AIR CLEANER AND DUST EJECTOR SERVICE (CONT)
REMARKS
ACTION
LOCATION/ITEM
Do not wash housing with water or clean with
11. Housing (22)
pressure air when it is on manifold. Dirt par-
ticles could be forced into engine.
Wipe clean with cloth.
CLEANING ELEMENT
Wear face shield and protective clothing to
prevent injury when using pressure air or
water. Use 30 psi maximum for cleaning.
Do not bump or tap element to clean. Do not
use element with damaged pleats, gaskets, or
seals. Discard damaged elements.
NOTE
Use pressure air, pressure water, or detergent
as necessary to clean primary element.
Replace primary element after six cleanings or
yearly.
Go on to Sheet 6
2-202