TM 10-3930-641-20
(Sheet 3 of 3)
BACKUP ALARM/START INTERLOCK SWITCH TESTING/ADJUSTMENT (CONT)
LOCATION/ITEM
ACTION
REMARKS
Multimet.er connected as in TESTING.
Loosen.
1. Actuator jam nut (1)
Put in REVERSE.
2. Transmission gear selector.
If ohms scale remains ∞ ohms, replace switch and actua-
a.
Turn in or out just until ohms scale reads
3. Actuator body (2)
ZERO, switch closes.
tor assembly. Repeat adjustment.
b. Turn (2) one additional turn in.
Go to TESTING, Step 1.
Tighten.
4. Actuator jam nut (1)
TA 098718
End
2-336