TM 10-3930-641-34-1
FUEL SHUTOFF SOLENOID REMOVAL AND INSTALLATION
(Sheet 2 of 3)
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
1. Fuel line support (2)
Remove.
2. Two capscrews (1) that secure
Remove.
shutoff solenoid
3. Solenoid
a. Remove.
b. Tag electric wires for assembly later.
c. Disconnect wires.
4. Spring (6), plunger (3) and shaft (5)
Remove from fuel pump rack lever.
5. Nut (4) and shaft (5)
Remove from plunger (3).
INSTALLATION
1. Nut (4)
a. Install on shaft (5) and shaft in plunger (3).
b. Adjust nut until dimension (X) is 1.39 in.
(35.3 mm).
NOTE
Dimension (X) is distance between nut and end
of opening in shaft.
2. Shaft (5), plunger (3) and spring (6)
b. Install as unit on fuel pump rack lever.
TA099005
Go on to Sheet 3
3-65