TM 10-3930-641-34-2
TORQUE CONVERTER INSTALLATION (CONT)
(Sheet 6 of 10)
LOCATION/ITEM
ACTION
REMARKS
16.
Two rings (68)
Remove from carrier assembly (62).
17.
Pin (66) that holds carrier (63) in
Remove.
position on carrier assembly (62)
18.
Carrier (63)
Remove from carrier assembly.
19.
Six capscrews (71) and washers (72),
Remove.
thirty-six capscrews (73) and
washers (74)
CAUTION
Do not let piston fall out of housing assembly
when housing assembly is removed.
20.
Housing assembly (58)
Fasten hoist and remove from converter
group. Housing assembly weighs 72 lb.
(33 Kg).
Go on to Sheet 7