TM 10-3930-675-10-1
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
Table 1. Preventive Maintenance Checks and
Services (PMCS) for RTCH-RT 240 - Continued.
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
49
Weekly
Fuel/Water
a. Turn drain knob counterclockwise and
(Con't)
Separator
drain all water from fuel/water separa-
tor.
b. Turn knob clockwise to close.
FUEL/WATER
SEPARATOR
DRAIN
KNOB
50
Weekly
Ether Quick-
Start System
WARNING
Ether is highly flammable and explosive. DO NOT perform ether
quick-start system checks or inspections while smoking or near
fire, flame, or sparks. Failure to follow this warning may cause a
fire or explosion, causing serious injury or death to personnel.
Check for loose connections and damage Damage is noted or canister is
to lines, fittings, and canister. Be alert for missing.
odor of leaking ether.
0013 00-16