TM 10-3930-675-10-1
ENGINE AIR CLEANER SERVICING - CONTINUED
0014 00
4.
Clean inside of housing with a clean, damp rag.
WARNING
Compressed air used for cleaning purposes should never exceed 30 psi (207 kPa). Wear protective
clothing (goggles/shield, gloves, etc.,) and use caution to avoid injury to personnel.
CAUTION
DO NOT pound or strike air cleaner elements against ground or other objects to attempt to knock
dirt from filter elements. Serious damage to elements will result, allowing dirt to enter engine intake
systems, causing major engine damage.
5.
Use compressed air, directed from the inside (clean air side) toward the outside, to remove dust and dirt from primary
and secondary filter elements.
6.
After cleaning with compressed air, inspect primary and secondary filter elements for tears or other damage. Replace
with new filter elements, if damaged.
7.
Install secondary filter element and seat inside housing. Install primary filter element.
8.
Install cover on housing and secure with six latches.
9.
Reset air cleaner restriction indicator.
END OF WORK PACKAGE
0014 00-2