TM 10-3930-675-10-2
OPERATION UNDER USUAL CONDITIONS - CONTINUED
0005 00
OPERATE LIFTING BOOM AND TOPHANDLER - CONTINUED
(4)
Press left button and multi-function trigger button to close tophandler from 40 to 20 ft (12.19 to 6.10 m) or
to close forklift tines, if forklift kit is installed.
374M-0054
e. Twistlock Lock/Unlock Button.
NOTE
When twistlocks are locked, GREEN indicator light on steering column inside cab and at end of
boom will illuminate. Three IR lights at end of boom also illuminates when operating in blackout
mode.
When twistlocks are unlocked, RED indicator light on steering column inside cab and at end of
boom will illuminate. Single IR light at end of boom also illuminates when operating in blackout
mode.
Press twistlock lock/unlock button and override switch at the same time to lock out or disable
boom lifting and lowering operation. Twistlock indicator light will turn off. To reactivate boom,
press twistlock lock/unlock button and override switch at the same time.
(1)
Press button to lock twistlocks, securing load.
(2)
Press button to unlock twistlocks, releasing load.
0005 00-14